67 research outputs found

    A Low Noise and High Dynamic Charge Sensitive Amplifier-Shaper associated with Silicon Strip Detector for Compton Camera in hadrontherapy

    No full text
    submitted to conference record of IEEE NSS-MIC, Anaheim USA, 29 october-3 november 2012International audienceA 8 channel Front End Electronics (FEE) circuit has been designed and fabricated in 0.35 ÎĽm CMOS process from Austria Micro System to be coupled with the Silicon Strip Detector (SSD) of the Compton Camera for quality control of hadrontherapy. Each channel includes a Charge Sensitive Amplifier (CSA) followed by two parallel CR-RC shapers. Slow and fast shapers, with 1 ÎĽs and 15 ns shaping time, are used to measure the energy and to time stamp all events respectively. The two sides of the SSD are read thanks to a configurable system for holes and electrons. The CSA presents an open loop gain of 67 dB and 90 degrees phase margin assuring a high stability. The circuit has been successfully tested. The test results are in good agreement with analytic and simulation calculations. Here, we describe the principles and present measured performances of the prototype. A high linearity over the range of 3E3 to 3E6 electrons is reached with a conversion gain of 3.6 mV/fC. The circuit achieves an ENC (Equivalent Noise Charge) of 412 electrons rms. 75% of the total noise is generated by the small value of the feedback resistor chosen to avoid pile up phenomenon due to the 1E5 hits/s occupancy rate. A cross-talk of 2 % was measured, 99% of which is due to the power supply disturbances. The power supply dissipation is 21 mW/channel for 3.3 V supply voltage. The area of this design is 2871Ă—1881 ÎĽm2 including pads

    A low power and low signal 5-bit 25MS/s pipelined ADC for monolithic active pixel sensors

    No full text
    For CMOS monolithic active pixels sensor readout, we developed a 5 bit low power analog to digital converter using a pipelined architecture. A non-resetting sample and hold stage is included to amplify the signal by a factor of 4. Due to the very low level of the incoming signal, this first stage compensates both the amplifier offset effect and the input common mode voltage dispersion. The converter consists of three 1.5 bit sub-ADC and a 2 bit flash. We present the results of a prototype, made of eight ADC channels. The maximum sampling rate is 25MS/s. The total DC power consumption is 1.7mW/channel on a 3.3V supply voltage recommended for the process. But at a reduced 2.5V supply, it consumes only 1.3mW. The size of each ADC channel layout is only 43ÎĽm*1.43mm. This corresponds to the pitch of two pixel columns each one would be 20ÎĽm wide. The full analog part of the converter can be quickly switched to a standby idle mode in less than 1ÎĽs; thus reducing the power dissipation to a ratio better than 1/1000. This fast shutdown is very important for the ILC vertex detector as the total DC power dissipation becomes directly proportional to the low beam duty cycle

    A low power and low signal 4 bit 50MS/s double sampling pipelined ADC for Monolithic Active Pixel Sensors

    No full text
    International audienceA 4 bit very low power and low incoming signal analog to digital converter (ADC) using a double sampling switched capacitor technique, designed for use in CMOS monolithic active pixels sensor readout, has been implemented in 0.35ÎĽm CMOS technology. A non-resetting sample and hold stage is integrated to amplify the incoming signal by 4. This first stage compensates both the amplifier offset effect and the input common mode voltage fluctuations. The converter is composed of a 2.5 bit pipeline stage followed by a 2 bit flash stage. This prototype consists of 4 ADC double-channels; each one is sampling at 50MS/s and dissipates only 2.6mW at 3.3V supply voltage. A bias pulsing stage is integrated in the circuit. Therefore, the analog part is switched OFF or ON in less than 1ÎĽs. The size for the layout is 80ÎĽm*0.9mm. This corresponds to the pitch of 4 pixel columns, each one is 20ÎĽm wide

    A low power and low signal 4 bit 50MS/s double sampling pipelined ADC for Monolithic Active Pixel Sensors

    No full text
    soumis à JINSTA 4 bit very low power and low incoming signal analog to digital converter (ADC) using a double sampling switched capacitor technique, designed for use in CMOS monolithic active pixels sensor readout, has been implemented in 0.35µm CMOS technology. A non-resetting sample and hold stage is integrated to amplify the incoming signal by 4. This first stage compensates both the amplifier offset effect and the input common mode voltage fluctuations. The converter is composed of a 2.5 bit pipeline stage followed by a 2 bit flash stage. This prototype consists of 4 ADC double-channels; each one is sampling at 50MS/s and dissipates only 2.6mW at 3.3V supply voltage. A bias pulsing stage is integrated in the circuit. Therefore, the analog part is switched OFF or ON in less than 1µs. The size for the layout is 80µm*0.9mm. This corresponds to the pitch of 4 pixel columns, each one is 20µm wide

    A low power and low signal 4 bit 50MS/s double sampling pipelined ADC for monolithie active pixel sensors

    Get PDF
    A 4 bit very low power and low incoming signal analog to digital converter (ADC) using a double sampling switched capacitor technique, designed for use in CMOS monolithic active pixels sensor readout, has been implemented in 0.35ÎĽm CMOS technology. A non-resetting sample and hold stage is integrated to amplify the incoming signal by 4. This first stage compensates both the amplifier offset effect and the input common mode voltage fluctuations. The converter is composed of a 2.5 bit pipeline stage followed by a 2 bit flash stage. This prototype consists of 4 ADC double-channels; each one is sampling at 50MS/s and dissipates only 2.6mW at 3.3V supply voltage. A bias pulsing stage is integrated in the circuit. Therefore, the analog part is switched OFF or ON in less than 1ÎĽs. The size for the layout is 80ÎĽm*0.9mm. This corresponds to the pitch of 4 pixel columns, each one is 20ÎĽm wide

    Instrumentation pour le suivi en ligne des traitements par hadronthérapie

    Get PDF
    National audienceInstrumentation for on-line monitoring of hadrontherapy treatments Localization of the dose deposited in the patient is a key point for the hadrontherapy cancer treatment. Different modalities of on-line control are explored, motivating acquisition systems and detectors developments, such as a Compton gamma camera, a proton trajectometer and a beam hodoscope

    Development of a Compton camera for medical applications based on silicon strip and scintillation detectors

    Get PDF
    International audienceA Compton camera is being developed for the purpose of ion-range monitoring during hadrontherapy via the detection of prompt-gamma rays. The system consists of a scintillating fiber beam tagging hodoscope, a stack of double sided silicon strip detectors (90 Ă‚ 90 Ă‚ 2 mm 3 , 2 Ă‚ 64 strips) as scatter detectors, as well as bismuth germanate (BGO) scintillation detectors (38 Ă‚ 35 Ă‚ 30 mm 3 , 100 blocks) as absorbers. The individual components will be described, together with the status of their characterization

    Real-Time Online Monitoring of the Ion Range by Means of Prompt Secondary Radiations

    Get PDF
    International audiencePrompt secondary radiations such as gamma rays and protons can be used for ion-range monitoring during ion therapy either on an energy-slice basis or on a pencil-beam basis. We present a review of the ongoing activities in terms of detector developments, imaging, experimental and theoretical physics issues concerning the correlation between the physical dose and hadronic processe

    2012 Activity Report of the Regional Research Programme on Hadrontherapy for the ETOILE Center

    Get PDF
    2012 is the penultimate year of financial support by the CPER 2007-2013 for ETOILE's research program, sustained by the PRRH at the University Claude Bernard. As with each edition we make the annual review of the research in this group, so active for over 12 years now. Over the difficulties in the decision-making process for the implementation of the ETOILE Center, towards which all our efforts are focussed, some "themes" (work packages) were strengthened, others have progressed, or have been dropped. This is the case of the eighth theme (technological developments), centered around the technology for rotative beam distribution heads (gantries) and, after being synchronized with the developments of ULICE's WP6, remained so by ceasing its activities, coinciding also with the retirement of its historic leader at IPNL, Marcel Bajard. Topic number 5 ("In silico simulations") has suffered the departure of its leader, Benjamin Ribba, although the work has still been provided by Branka Bernard, a former postdoctoral fellow in Lyon Sud, and now back home in Croatia, still in contract with UCBL for the ULICE project. Aside from these two issues (and the fact that the theme "Medico-economical simulations" is now directly linked to the first one ("Medical Project"), the rest of the teams are growing, as evidenced by the publication statistics at the beginning of this report. This is obviously due to the financial support of our always faithful regional institutions, but also to the synergy that the previous years, the European projects, the arrival of the PRIMES LabEx, and the national France Hadron infrastructure have managed to impulse. The Rhone-Alpes hadron team, which naturally includes the researchers of LPC at Clermont, should also see its influence result in a strong presence in France Hadron's regional node, which is being organized. The future of this regional research is not yet fully guaranteed, especially in the still uncertain context of ETOILE, but the tracks are beginning to emerge to allow past and present efforts translate into a long future that we all want to see established. Each of the researchers in PRRH is aware that 2013 will be (and already is) the year of great challenge : for ETOILE, for the PRRH, for hadron therapy in France, for French hadrontherapy in Europe (after the opening and beginning of treatments in the German [HIT Heidelberg, Marburg], Italian [CNAO, Pavia] and Austrian [MedAustron, Wien Neuerstadt]) centers. Let us meet again in early 2014 for a comprehensive review of the past and a perspective for the future ..
    • …
    corecore